NBL 12V 26Ah Flooded Lead‑Acid Solar Battery – EB‑26
NBL 12V 26Ah Flooded Lead‑Acid Solar Battery – EB‑26 is backordered and will ship as soon as it is back in stock.
Delivery, Shipping & Returns
Delivery, Shipping & Returns
1. Delivery Policy
All orders are processed and delivered by our delivery team within 1 day within Kampala. If your location is out of Kampala, please allow an additional day in transit for delivery. If there will be a significant delay in shipment of your order, we will contact you via telephone.
2. Returns (refunds and exchanges)
If you are unhappy with your item, please let us know. We only replace items if they are defective or damaged. If you need to exchange an item for the same item, please inform us via telephone or send us an email at sales@kwttechmart.ug and bring your item to our store.
Our refund and returns policy lasts 14 days. If 14 days have passed since your purchase, we can’t offer you a full refund or exchange. To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.
Bring proof of purchase (receipt, order confirmation page, order details page) and payment method used to make the original purchase.
NBL 12V 26Ah Flooded Lead‑Acid Solar Battery – EB‑26 is backordered and will ship as soon as it is back in stock.
Key Features of a 12 V 26 Ah Flooded LeadAcid Battery
Nominal Voltage & Capacity: 12 V nominal, ~26 Ah at 20hour rate (≈1.3 A discharge) and
about 24–25 Ah at 10hour rate
Internal resistance: Approximately 11–12 mΩ (measured at 25 °C
Dimensions & Weight: Roughly 166 × 175 × 125 mm; weight in the range of 7.7–8.0 kg
Charge Voltage Specifications:
o Cycle charging: ~14.1–14.4 V (adjusted –3 mV/°C/cell)
o Float (standby): ~13.5–13.8 V
Self-discharge: ~9% loss over 3 months; ~18% over 6 months at 25 °C
Temperature performance: Optimal output at 25 °C (~100%); drops to ~85% at 0 °C and
~65% at –15 °C
⚙️ Typical Structure (Flooded Type)
Multiple leadantimony calcium alloy plates immersed in sulfuric acid electrolyte.
Each cell topped via vent caps to add distilled water and vent hydrogen gas.
Heavy-duty tubular or flat plate design for deep-cycle endurance and high cycling life.
Serviceable by design: hydrometer ports and refill caps.
-